24/7 customer support+44 (0) 345 676 9733
Lavender Medical, 646 Blackhorse Road, Letchworth Garden City, SG6 1HD

Key Benefits of the FlexPasser® Tendon Retrieval Kit:

  • Minimally invasive access: Retrieve retracted flexor tendon ends through smaller incisions, reducing soft tissue disruption.
  • Lower risk of tendon damage: Designed to minimize trauma to the tendon end and sheath when compared to standard retrieval techniques*.
  • Improved surgical outcomes: Reduced trauma may lower the risk of post-operative adhesions, helping to preserve range of motion and function.
  • Versatile application: Suitable for both single and dual flexor tendon retrieval procedures.
  • Avoid repeat suturing: Accurate retrieval may eliminate the need for repeated tendon end suturing, saving time and reducing complications.

FlexPasser® Tendon Retrieval Kit – Minimally Invasive Solution for Flexor Tendon Repair

The FlexPasser® Tendon Retrieval Kit is a single-use surgical instrument system designed to assist in the precise retrieval of retracted proximal tendon stumps during the repair of lacerated digital flexor tendons in the hand. This innovative tool supports minimally invasive tendon retrieval while reducing the risk of additional trauma.

*Based on cadaveric model trials

How it works

Step 1. The proximal tendon stump is delivered to the palm via a small incision in the crease of the palm, or proximal point of choice if the vinculum is to be preserved. The palm is preferred, to minimise incisions on the digit.


Step 2. The finger should be gently extended. The probe is advanced with its round end leading through the flexor sheath, from the site of the distal flexor stump/opening in the sheath to the site of the proximal flexor stump. Hold the device close to the tip and advance in stages, maintaining the orientation of the probe to avoid buckling and rotation.


Step 3. Maintain the probe’s orientation as it is pulled through the proximal incision, leaving the plastic sleeve in place protruding from both incisions, ensure the sleeve has not twisted before proceeding.


Step 4. The full thickness of one leg of the sleeve is cut across obliquely at the base of the tapered segment. The oblique cut creates a larger entry point for the tendon than a transverse cut.


Step 5. The leg that has not been cut can be removed from the digit, leaving a single sleeve in place.


Step 6. The proximally retracted flexor tendon stump is sutured using the surgeon’s preferred technique for the repair, leaving the suture ends long enough for retrieval. The needle is to be kept on the suture.


Step 7. The free end of the suture is introduced into the open end of the needle carrier to about 4-5 cm. Then, using a needle holder, the entire body of the curved needle is introduced in the carrier antegrade, gently curving the carrier to preserve the needle tip.


Step 8. The Integrated probe and needle carrier is threaded through the plastic sleeve from the proximal to distal incisions and removed at the distal incision, once the needle and suture have been passed through the sleeve they can be released from the carrier.


Step 9. We recommend that a small volume of saline should be used to lubricate the sleeve and tendon prior to passing the tendon through the plastic sleeve lining the sheath. Gentle traction is applied to both ends of the suture, whilst the plastic sleeve is held in place with forceps at the proximal incision, to guide the proximal tendon stump(s) through the cavity of the sleeve and to the distal wound.

FlexPasser™ Tendon Retrieval Kit Dual Tendon Technique, Surgical Technique Animation

FlexPasser™ Tendon Retrieval Kit, Cadaveric Surgical Technique Video

Contact Us For Any orthopaedic implants and materials Information Or Needs

Contact UsOur Products

Our Ethos

  • To have and maintain the highest quality of service to our clients
  • To bring high quality, innovative products to the UK market
  • To deliver value for money to our clients
  • To work with all our clients to help them deliver the best care to their patients
  • Teamwork and integrity in all relationships