The FlexPasser™ Tendon Retrieval Kit is a single-use instrument set for retrieving retracted proximal tendon stumps during repair of lacerated digital flexor tendons in the hand. A probe carries a plastic sleeve through the flexor sheath between the distal and proximal incisions; the sutured tendon stump is then drawn through the sleeve to the repair site, so the tendon is retrieved through small incisions.
Features
- Retrieval of retracted flexor tendon ends through small incisions
- Sleeve lines the flexor sheath while the tendon is passed, designed to reduce the risk of damage to the tendon end (manufacturer cadaver trials)
- Suitable for single and dual flexor tendon retrieval
- Potential to avoid repeat suturing of the tendon end
Indications
The FlexPasser™ Tendon Retrieval Kit is indicated for patients undergoing repair of lacerated flexor tendons in the hand.
Contraindications
The kit must not be used for any procedure other than the intended use.
Indications, contraindications, warnings and precautions are listed in the instructions for use (IFU).
How it works
Step 1. The proximal tendon stump is delivered to the palm via a small incision in the crease of the palm, or proximal point of choice if the vinculum is to be preserved. The palm is preferred, to minimise incisions on the digit.
Step 2. The finger should be gently extended. The probe is advanced with its round end leading through the flexor sheath, from the site of the distal flexor stump/opening in the sheath to the site of the proximal flexor stump. Hold the device close to the tip and advance in stages, maintaining the orientation of the probe to avoid buckling and rotation.
Step 3. Maintain the probe’s orientation as it is pulled through the proximal incision, leaving the plastic sleeve in place protruding from both incisions, ensure the sleeve has not twisted before proceeding.
Step 4. The full thickness of one leg of the sleeve is cut across obliquely at the base of the tapered segment. The oblique cut creates a larger entry point for the tendon than a transverse cut.
Step 5. The leg that has not been cut can be removed from the digit, leaving a single sleeve in place.
Step 6. The proximally retracted flexor tendon stump is sutured using the surgeon’s preferred technique for the repair, leaving the suture ends long enough for retrieval. The needle is to be kept on the suture.
Step 7. The free end of the suture is introduced into the open end of the needle carrier to about 4-5 cm. Then, using a needle holder, the entire body of the curved needle is introduced in the carrier antegrade, gently curving the carrier to preserve the needle tip.
Step 8. The Integrated probe and needle carrier is threaded through the plastic sleeve from the proximal to distal incisions and removed at the distal incision, once the needle and suture have been passed through the sleeve they can be released from the carrier.
Step 9. We recommend that a small volume of saline should be used to lubricate the sleeve and tendon prior to passing the tendon through the plastic sleeve lining the sheath. Gentle traction is applied to both ends of the suture, whilst the plastic sleeve is held in place with forceps at the proximal incision, to guide the proximal tendon stump(s) through the cavity of the sleeve and to the distal wound.

Sizes and ordering
Code from xiros.co.uk. The Xiros Product Portfolio (LAB 142 rev 6.00, January 2025) prints it without the suffix, as 202-1500.
FlexPasser™ Tendon Retrieval Kit1 item
| Ref. | Description |
|---|---|
| 202-1500U | FlexPasser™ Tendon Retrieval Kit (supplied sterile, single use) |
Codes and sizes are taken from the manufacturer's marketing literature and may change. For current information, check the Xiros website or the instructions for use before ordering.
Surgical Technique & Brochures
FlexPasser™ Tendon Retrieval Kit, Single Tendon Retrieval Surgical Technique Animation
FlexPasser™ Tendon Retrieval Kit, Dual Tendon Retrieval Surgical Technique Animation
FlexPasser™ Tendon Retrieval Kit, Cadaveric Surgical Technique Video
FlexPasser™ Tendon Retrieval Kit Technique Animation
FlexPasser™ Flexor Tendon Retrieval
Product information
Materials
Stainless steel, low-density polyethylene (LDPE) and fluorinated ethylene propylene (FEP).
How is the kit supplied?
Sterile (gamma irradiated) in a double pouch. The kit is for single use only and is not for implantation.
Which needles can be used?
Needles of 11 to 26 mm can be used with the needle carrier; a 3/8 circle needle is recommended.
Is the kit suitable for every digit?
The kit may not be suitable for smaller digits.
Instructions for use
Instructions for use are available in the Xiros IFU library.
Related Products

ApeX – Interphalangeal Fusion
Zero-profile post-and-screw implant for arthrodesis of the interphalangeal joints of the hand, at a 30° or 45° fusion angle.
View product
XMCP – Metacarpal Phalangeal Fusion
Zero-profile intramedullary fusion device with a fixed 25° angle for compression arthrodesis of the metacarpophalangeal joint.
View product
NeoSpan® SE Compression Staples for Hand
Superelastic compression staple with a stepped-tooth design for fixation of fusions and osteotomies of the bones of the hand.
View product
